2.4GPM Tankless Gas Water Heater
2.4GPM Tankless Gas Water Heater
24 months limited warranty
- 16.1" x 16.1"
- 18.1" x 16.1"
- 18.1" x 18.1"
- White
- Black
$814.90
-
Hot water on-demand
DescriptionThe gas water heater has been engineered with advanced safety features including a pressure relief valve, over temperature protection, blower block protection and automatic shut off. Advanced engineering has created a vortex pattern inside the water mixing chamber to eliminate high temperature fluctuations to reduce the risk of hot water scalding when multiple water outlets are in use.
Key FeaturesHight Heating Capacity
Consistent Temperature
Electronic Ignition
Over Temperature Protection
Auto Turn Off
Wall Controller
Low Pressure Alarm
Pressure Relief Valve
Retrofit Design
-
- Temperature Range
- Water Flow
- Heating Capacity
- Safety Features
- Gas Supply
- Electricity Supply
- Water Supply
- Dimensions
-
Temperature RangeTemperature Setting Range: 95 -124°F (35 - 51°C)
Default setting temperature: 115°F (46°C)
Temperature Stability: Furrion Vortex Water Mixing Technology
(±1.8-2.6°F (1-2°C)) -
Water FlowOperating Water Flow: 0.32 GAL (1.2L)/min
Low Water Flow Protection: Auto Cut-o <0.32 GAL (1.2L)/min -
Heating CapacityAutomatic ignition: √
Input BTU: 13,000 ~ 60,000BTU
Heating Elements: Copper Heat Exchanger
Thermal Efficiency: ≥81% -
Safety FeaturesOver Current Protection: 10 Amp Fuse
High Water Pressure Protection: ≥87psi (6bar)Auto Release Pressure Valve
Over Temperature Protection:
Software Protection - 136°F, ±1.8°F (76°C, ±1°C)
Thermal Sensor - 135°F, ±14.4°F (75°C, ±8°C)
Exhaust Blocking Protection: √ -
Gas SupplyGas Supply: LP (Propane) Only
Gas Inlet Pressure: 11 - 14” WC
Gas Line Connector: UNF 5/8'' – 18 -
Electricity SupplyElectric Power Supply: DC 12V 3A
-
Water SupplyWorking Pressure (Water Inlet): 10 - 65 PSI (0.68 - 4.5bar)
Water Flow: 0.32 GAL/min (1.2L) – 2.4 GAL/min (9L)
Water Inlet Connector: 1/2” NPT
Water Outlet Connector: 1/2” NPT
-
DimensionsProduct Dimensions (W x H x D): 12.81 x 12.62 x 20.75”
324 x 320 x 526.6mm
Net Weight (Ibs/kg): 27.6 / 12.5
-
Fuses are designed as a safety mechanism and blow to prevent a dangerous situation. If your fuse is blowing when you turn the RV water heater on, there may be an issue with the power connection. Ensure that the power to the unit is 12 volt DC and in the correct polarity. If this problem persists, please get in touch with your local service center or Furrion directly.
No, this RV water heater model does not have freeze protection. You will need to ensure that your unit is properly winterized. However, our climate resistance circuit boards do function at sub-zero temperatures and throughout extreme summer heats.
Furrion RV water heaters are rated for use up to 4500 ft. However, please note that at these extreme altitudes, some reduction in water flow rate and performance may be experienced.
Furrion RV water heaters use 5mm x 20mm 120 volts 10 amp glass fuses.
If you have experienced an E5 error code while using your Furrion RV water heater, it suggests an issue related to air pressure. First, ensure that there is no wind blowing directly into the exhaust of the unit. You may need to reorient your RV if necessary. The problem could also be caused by a blockage in the exhaust that needs to be cleared. If neither of these solutions resolves your error, then please contact Furrion directly.
One of the most common reasons for there being no water flow is because shutoff valves are accidentally turned off. Ensure that all shutoffs are turned back on after installation, and turn the pressure relief valve to see if water is flowing through your heater. If neither of these problems helps, please contact your local service center or Furrion directly.
If you’ve encountered a situation where there is no hot water flowing through your camper water heater and the wall controller unit does not show the unit as running, you may have positioned the bypass valve incorrectly. You can also try turning the pressure relief valve to see if water is flowing through the heater. If neither of these two solutions helps, please contact your local service center or Furrion for assistance.
Furrion RV water heaters provide on-demand hot water rated for up to 65 PSI of pressure. If the pressure exceeds this, then the unit might leak from the pressure relief valve and a regulator may be needed.
Different door sizes may be selected based on your camper and what size space you have, but the hot water heater inside will remain the same size and with the same specifications.
If you notice your RV water heater not heating to the temperature you selected on the wall controller, this could be because of a number of reasons. The first thing you should do is check for mixing valves or faucets in the system that could be causing hot and cold water to mix, leading to a lower than the selected temperature. Beyond this, check if the RV has an outside faucet and be sure that both the cold and hot water valves are closed, and the nozzle is removed.
The Furrion tankless water heater for RVs is a 2.4GPM gas heater but can come with a range of different door sizes.
For white doors, the sizes are: 16 1/8" x 16 1/8" , 16 1/8" x18 1/8" , 18 1/8" x 18 1/8".
For black doors, the size is 16 1/8" x 16 1/8".Show moreShow less